440.22 Short-Circuit and Ground-Fault Protection Devices for A/C and Refrigeration Equipment

What's Wrong Here?

Code Q&A

Code Quiz

Deadline Fast Approaching

Visit The EC&M e-Tradeshow


About this Newsletter
This twice-a-month
e-newsletter is brought to you from the publisher of EC&M magazine.

CodeWatch will:

  • Let you know what could be changing in the Code®.
  • Help you brush up on your ability to apply the Code®.
  • Test your knowledge of the Code® with a Q&A format.
  • Provide information on upcoming Code® seminars and shows.
  • Give you an opportunity to sound off on Code®-related issues.

    We want to make sure we're providing you with the content you need to better manage your business or enhance your technical skills. E-mail us and let us know what you want to see in future issues of this e-newsletter. We will do our best to address your request in a future issue of CodeWatch.


  • Subscriptions
    To unsubscribe from this newsletter go to: Unsubscribe

    To subscribe to this newsletter, go to: Subscribe

    To get this newsletter in a different format (Text or HTML), or to change your e-mail address, please visit your profile page to change your delivery preferences.


    Back Issues
    Missed an issue? Visit the CodeWatch archive on EC&M's Web site.

    Tell a friend about CodeWatch
    Do you know of someone who'd like to receive CodeWatch? Visit the subscriber site, enter their e-mail address and spread the wealth!


    Advertising
    To find out how to advertise in this newsletter, e-mail David Miller or call him at (312) 840-8487.

    The designations "National Electrical Code? and ?NEC? refer to the National Electrical Code®, which is a registered trademark of the National Fire Protection Association.

     
    ADVERTISEMENT



    ADVERTISEMENT


    Top 50 NEC Rules
















    440.22 Short-Circuit and Ground-Fault Protection Devices for A/C and Refrigeration Equipment

    By Mike Holt
    Short-circuit and ground-fault protection for air-conditioning and refrigeration equipment must be sized no larger than identified on the equipment's nameplate. If the equipment doesn't have a nameplate specifying the size and type of protection device, then the protection device must be sized in accordance with (A) or (B).

    (A) One Motor Compressor. The short-circuit and ground-fault protection device must not be greater than 175% of the motor-compressor current rating. If the protection device sized at 175% isn't capable of carrying the starting current of the motor-compressor, the next size larger protection device can be used, but in no case can it exceed 225% of the motor-compressor current rating.

    (B) Rating for Equipment. Where the equipment incorporates more than one hermetic refrigerant motor-compressor, or a hermetic refrigerant motor-compressor and other motors or other loads, the equipment short-circuit and ground-fault protection must be sized as follows:
    (1) Motor-Compressor Largest Load. The rating of the branch-circuit short-circuit and ground-fault protective device must not be greater than the largest motor-compressor short-circuit ground-fault protection device, plus the sum of the rated load currents of the other compressors.

    The branch-circuit conductors are sized at 125% of the larger motor-compressor current, plus the sum of the rated load currents of the other compressors [440.33].

    Editor's note: This information was extracted from Mike Holt's textbook, Understanding the National Electrical Code


    ADVERTISEMENT
    The Fluke 1735 Power Logger is the ideal electrician or technician's power meter for conducting energy studies and basic power quality logging. Set the Power Logger up in seconds with the included flexible current probes and color display. The power quality meter measures most electrical power parameters, harmonics, and captures voltage events. www.fluke.com/codewatch

    Code Challenge
    What's Wrong Here?
    By Joe Tedesco
    Think you know how this installation violates the NEC? Visit EC&M's Web site to see the answer.

    Hint: Damaged equipment in Las Vegas.


    Code Q&A
    By Mike Holt
    Q. A 400A service is made up of two 200A main breaker panelboards that are nippled together. Can the service conductors pass through one of the cabinets to supply the other panelboard?

    Visit EC&M's Web site to see the answer.


    Code Quiz
    By Steven Owen
    Q. What is the allowable ampacity of any one of the current-carrying 12 AWG THHN insulated conductors installed in a cellular concrete floor raceway with 29 other current-carrying 12 AWG THHN conductors and five equipment grounding conductors? Disregard the terminals in your calculations.

    1. 30A
    2. 20A
    3. 13.5A
    4. 11.25A

    Visit EC&M's Web site for the answer and explanation.


    ADVERTISEMENT
    A full week devoted to your Arc Flash Safety Needs! Learn how to do Arc Flash analysis, gain a full day of NFPA-70E Safety specifics, and Witness an actual Arc Blast during our Arc Flash Safety Emphasis Week: March 31 — April 4, 2008 in Boston, MA. Streamline your Electrical Safety Program; what used to take hours, now takes mere seconds with EasyPower! Learn more: www.easypower.com/support_training.php

    Code News Update
    Deadline Fast Approaching
    The Notice of Intent to Make a Motion closing date for the next revision of NFPA 70E: Standard for Electrical Safety in the Workplace is April 4, 2008. This standard addresses "electrical safety requirements for employee workplaces that are necessary for the practical safeguarding of employees in their pursuit of gainful employment." The posting of certified Notice of Intent to Make an NEC Motions (NITMAMs) is scheduled to take place on May 4, 2008.


    ADVERTISEMENT
    Cool Electronic Cabinets
    Stop electronic control downtime due to heat, dirt and moisture. UL Listed Cabinet Coolers from EXAIR produce 20 degree Fahrenheit air from an ordinary supply of compressed air to cool electrical controls. Thermostat control minimizes air usage. Maintains the NEMA 4, 4X (stainless steel) and 12 rating of the enclosure. Web site offers detailed information, downloadable drawings and PDF literature.
    www.exair.com/15/540_03a.htm


    Shows and Events


    Visit The EC&M e-Tradeshow
    Look for these FREE live conferences, scheduled for 2008:

    • Using the Electrical Designer's Reference Software Program
    • The NEC in Construction Litigation
    • Understanding Electrical Safety and PPE Selection
    • Implementing an Arc Flash Safety Compliance Program
    • Preparing an Arc Flash Hazard Study
    • Proper Working Drawings: An Engineer's Perspective
    Visit the many exhibitors in this virtual tradeshow and take a look at the On-Demand Theater, where you can view past online conferences 24/7/365. Go to e-tradeshow for information on accessing the EC&M e-Tradeshow and visiting the On-Demand Library.



    ADVERTISEMENT
    Eliminate Red Tags
    It takes more than the UL Mark on a product to satisfy code requirements. Before your next installation, use UL's Code Compliance Database to identify the correlation between model codes and UL Certified products, as well as find manufacturers of certified products.

    Click here today to find up-to-date UL Listed products at the UL Code Correlation Database.


    You are subscribed to this newsletter as #email#

    For questions concerning delivery of this newsletter, please contact our Customer Service Department at:
    Customer Service Department
    EC&M
    A Penton Media publication
    US Toll Free: 866-505-7173
    International: 847-763-9504
    Email:ecmweb@pbinews.com

    Penton | 1166 Avenue of the Americas, 10th Floor | New York, NY 10036

    Copyright 2014, Penton. All rights reserved. This article is protected by United States copyright and other intellectual property laws and may not be reproduced, rewritten, distributed, re-disseminated, transmitted, displayed, published or broadcast, directly or indirectly, in any medium without the prior written permission of Penton Media, Inc.